1 medium-voltage switchgear
- распределительное устройство среднего напряжения
- комплектное распределительное устройство среднего напряжения
комплектное распределительное устройство среднего напряжения
-Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.
Safety enclosed switchgear may be classified with respect to purpose of application as follows:
1. General medium- or high- voltage switchgear
2. Primary unit substations
3. Rectifier unit substations
4. Secondary unit substations or power centers
5. General low-voltage switchgear
6. Low-voltage distribution switchboards
7. Motor-control-center switchboards
[American electricians’ handbook]
Medium-voltage switchgear (Fig. 4.115) provides for the required control and metering equipment for generators, transformer supply circuits, feeders, large motors, etc., for systems with voltage up to 15,000 V. A large variety of standardized units is available
FIGURE 4.115 Medium-voltage metal-enclosed switchgear. [Westinghouse Electric Corp.][American electricians’ handbook]
Тематики
- комплектное распред. устройство (КРУ)
Синонимы
EN
распределительное устройство среднего напряжения
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > medium-voltage switchgear
-
2 medium-voltage switchgear
Большой англо-русский и русско-английский словарь > medium-voltage switchgear
-
3 medium-voltage switchgear
высоковольтное распределительное устройство на напряжение ниже 100 кВАнгло-русский словарь технических терминов > medium-voltage switchgear
-
4 medium-voltage switchgear
Универсальный англо-русский словарь > medium-voltage switchgear
-
5 arc-proof low voltage switchgear and controlgear assembly
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof low voltage switchgear and controlgear assembly
-
6 switchgear
1) эл. распределительное устройство3) ж.-д. стрелочный привод•-
armorclad switchgear
-
carriage-type switchgear
-
drawout switchgear
-
factory-assembled switchgear
-
gas-insulated switchgear
-
high-voltage switchgear
-
indoor switchgear
-
liquid-insulated switchgear
-
low-voltage switchgear
-
medium-voltage switchgear
-
metalclad switchgear
-
outdoor switchgear
-
pad-mounted switchgear
-
SF6 breaker switchgear
-
SF6 insulated switchgear
-
vacuum breaker switchgear -
7 switchgear of the draw-out type
Шкаф с выдвижными блоками
Рис. Schneider Electric
Выдвижной блок
Рис. Schneider ElectricS afety enclosed switchgear of the truck or draw-out type (Figs. 4.113 and 4.114) consists of a steel enclosure mounted on an angle-iron framework. All apparatus which requires attention or inspection is mounted on a truck or draw-out structure.
FIGURE 4.113 Draw-out type of safety enclosed vacuum circuit-breaker switchgear
assembly.
[Siemens Energy & Automation, Inc.]
FIGURE 4.114 Draw-out type of vacuum circuit-breaker.
[Siemens Energy & Automation, Inc.]The equipment for each circuit is mounted on either a separate truck, which can easily be rolled out from the rest of the structure, or a metal structure supported on guides so that it can easily be slid in and out from the enclosure (Fig. 4.114).
[American electricians’ handbook]
Metal Clad Withdrawable Switchgear
[ http://en.daqo.com/Medium-Voltage-Switchgear-UR4_42.html]
Тематики
- НКУ (шкафы, пульты,...)
Обобщающие термины
EN
Англо-русский словарь нормативно-технической терминологии > switchgear of the draw-out type
-
8 switchgear of the truck type
Шкаф с выдвижными блоками
Рис. Schneider Electric
Выдвижной блок
Рис. Schneider ElectricS afety enclosed switchgear of the truck or draw-out type (Figs. 4.113 and 4.114) consists of a steel enclosure mounted on an angle-iron framework. All apparatus which requires attention or inspection is mounted on a truck or draw-out structure.
FIGURE 4.113 Draw-out type of safety enclosed vacuum circuit-breaker switchgear
assembly.
[Siemens Energy & Automation, Inc.]
FIGURE 4.114 Draw-out type of vacuum circuit-breaker.
[Siemens Energy & Automation, Inc.]The equipment for each circuit is mounted on either a separate truck, which can easily be rolled out from the rest of the structure, or a metal structure supported on guides so that it can easily be slid in and out from the enclosure (Fig. 4.114).
[American electricians’ handbook]
Metal Clad Withdrawable Switchgear
[ http://en.daqo.com/Medium-Voltage-Switchgear-UR4_42.html]
Тематики
- НКУ (шкафы, пульты,...)
Обобщающие термины
EN
Англо-русский словарь нормативно-технической терминологии > switchgear of the truck type
-
9 switchgear
- распределительное устройство
- коммутационное устройство
- коммутационная аппаратура
- аппаратура распределения
аппаратура распределения
Общий термин для коммутационных аппаратов и их комбинаций с относящимися к ним устройствами управления, измерения, защиты и регулирования, а также для узлов, в которых такие аппараты и устройства соединяются с соответствующими фидерами, комплектующим оборудованием, оболочками и опорными конструкциями, предназначенных, в принципе, для использования в системах производства, передачи, распределения и преобразования электрической энергии.
МЭК 60050(441-11-02).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switchgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures, intended in principle for use in connection with generation, transmission, distribution and conversion of electric energy
[IEV number 441-11-02]FR
appareillage de connexion
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les supports correspondants, destinés en principe à être utilisés dans le domaine de la production, du transport, de la distribution et de la transformation de l'énergie électrique
[IEV number 441-11-02]Тематики
- аппарат, изделие, устройство...
EN
DE
- Schaltanlagen und/oder Schaltgeräte für Energieverteilung
FR
коммутационная аппаратура
коммутационное оборудование
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
Синонимы
EN
коммутационное устройство
Устройство, предназначенное для обеспечения или прерывания подачи электрического тока в электрические цепи.
Примечание - Коммутационное устройство может выполнять одну или обе эти функции.
[ГОСТ ЕН 1070-2003]
коммутационное устройство
-
[IEV number 442-01-46]EN
switching device
a device designed to make or break the current in one or more electric circuits
Source: 441-14-01 MOD
[IEV number 442-01-46]
switchgear
any of several devices used for opening and closing electric circuits, esp those that pass high currents
[Collins]FR
dispositif de coupure
Параллельные тексты EN-RU
appareil destiné à établir ou à interrompre le courant dans un ou plusieurs circuits électriques
Source: 441-14-01 MOD
[IEV number 442-01-46]distribution board
assembly containing different types of switchgear and controlgear associated with one or more outgoing electric circuits fed from one or more incoming electric circuits, together with terminals for the neutral and protective conductors.
[IEV number 826-16-08]распределительная панель
НКУ, состоящее из коммутационных устройств или устройств защиты (например, плавких предохранителей), присоединенных к одной или нескольким выходным цепям с питанием от одной или нескольких входящих цепей, а также зажимов для нейтрального проводника и проводников цепей защиты. Оно может также содержать сигнальные устройства и другие устройства контроля.
[ ГОСТ Р 51321. 3-99 ( МЭК 60439-3-90)]
Тематики
- аппарат, изделие, устройство...
EN
DE
FR
распределительное устройство
Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
[РД 34.20.185-94]
распределительное устройство
Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
[ ГОСТ 24291-90]
[ ГОСТ Р 53685-2009]
электрическое распределительное устройство
распределительное устройство
Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
[ОСТ 45.55-99]
распределительное устройство
Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
[ПОТ Р М-016-2001]
[РД 153-34.0-03.150-00]
устройство распределительное
Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
switching substation
a substation which includes switchgear and usually busbars, but no power transformers
[IEV number 605-01-02]FR
poste de sectionnement
poste de coupure
poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
[IEV number 605-01-02]В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.
[ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:
-
по назначению:
- генерирующие,
- преобразовательно-распределительные,
-
потребительские.
Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;
-
по роду тока:
- постоянного тока,
- переменного тока.
-
по напряжению:
- до 1000 В,
- выше 1000 В.
ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:
Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласнодля электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.-
по способу присоединения к электросети ПС разделяются на:
- тупиковые (блочные),
- ответвительные (блочные),
- проходные (транзитные)
- узловые.
Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.
Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.
Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.
Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.-
по способу управления ПС могут быть:
- только с телесигнализацией,
- телеуправляемыми с телесигнализацией,
- с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).
Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.
В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.
В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.[ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
Several different classifications of switchgear can be made:- By the current rating.
-
By interrupting rating (maximum short circuit current that the device can safely interrupt)
- Circuit breakers can open and close on fault currents
- Load-break/Load-make switches can switch normal system load currents
- Isolators may only be operated while the circuit is dead, or the load current is very small.
-
By voltage class:
- Low voltage (less than 1,000 volts AC)
- Medium voltage (1,000–35,000 volts AC)
- High voltage (more than 35,000 volts AC)
-
By insulating medium:
-
By construction type:
- Indoor (further classified by IP (Ingress Protection) class or NEMA enclosure type)
- Outdoor
- Industrial
- Utility
- Marine
- Draw-out elements (removable without many tools)
- Fixed elements (bolted fasteners)
- Live-front
- Dead-front
- Open
- Metal-enclosed
- Metal-clad
- Metal enclosed & Metal clad
- Arc-resistant
-
By IEC degree of internal separation
- No Separation (Form 1)
- Busbars separated from functional units (Form 2a, 2b, 3a, 3b, 4a, 4b)
- Terminals for external conductors separated from busbars (Form 2b, 3b, 4a, 4b)
- Terminals for external conductors separated from functional units but not from each other (Form 3a, 3b)
- Functional units separated from each other (Form 3a, 3b, 4a, 4b)
- Terminals for external conductors separated from each other (Form 4a, 4b)
- Terminals for external conductors separate from their associated functional unit (Form 4b)
-
By interrupting device:
-
By operating method:
- Manually operated
- Motor/stored energy operated
- Solenoid operated
-
By type of current:
-
By application:
-
By purpose
- Isolating switches (disconnectors)
- Load-break switches.
- Grounding (earthing) switches
A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.
Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.
[Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
[ http://en.wikipedia.org/wiki/High_voltage_switchgear]Тематики
- электрификация, электроснабж. железных дорог
- электроагрегаты генераторные
- электробезопасность
- электроснабжение в целом
Синонимы
EN
- distribution
- energy distribution board
- gear
- switch-gear
- switchboard
- switchgear
- switching substation
- switchyard
DE
FR
Англо-русский словарь нормативно-технической терминологии > switchgear
-
10 arc-proof switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchgear
-
11 arc-resistant switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-resistant switchgear
-
12 internal arc-proof switchgear and controlgear assemblу
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > internal arc-proof switchgear and controlgear assemblу
-
13 withdrawable switchgear
Шкаф с выдвижными блоками
Рис. Schneider Electric
Выдвижной блок
Рис. Schneider ElectricS afety enclosed switchgear of the truck or draw-out type (Figs. 4.113 and 4.114) consists of a steel enclosure mounted on an angle-iron framework. All apparatus which requires attention or inspection is mounted on a truck or draw-out structure.
FIGURE 4.113 Draw-out type of safety enclosed vacuum circuit-breaker switchgear
assembly.
[Siemens Energy & Automation, Inc.]
FIGURE 4.114 Draw-out type of vacuum circuit-breaker.
[Siemens Energy & Automation, Inc.]The equipment for each circuit is mounted on either a separate truck, which can easily be rolled out from the rest of the structure, or a metal structure supported on guides so that it can easily be slid in and out from the enclosure (Fig. 4.114).
[American electricians’ handbook]
Metal Clad Withdrawable Switchgear
[ http://en.daqo.com/Medium-Voltage-Switchgear-UR4_42.html]
Тематики
- НКУ (шкафы, пульты,...)
Обобщающие термины
EN
Англо-русский словарь нормативно-технической терминологии > withdrawable switchgear
-
14 enclosed assembly (of switchgear and controlgear)
НКУ защищенное
НКУ закрытое со всех сторон (за возможным исключением монтажной поверхности), в котором после его установки обеспечивается степень защиты не менее IP2X.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
защищенное НКУ
НКУ, конструкция которого обеспечивает требуемую степень защиты со всех сторон от прикосновения к частям, находящимся под напряжением (за исключением монтажной поверхности).
[ ГОСТ Р МЭК 61439.1-2013]EN
enclosed assembly (of switchgear and controlgear)
an assembly enclosed on all sides, top and bottom in such a manner as to provide a specified degree of protection
NOTE – The mounting surface may form a part of the enclosure when specified in the relevant publication.
[IEV number 441-12-02]FR
ensemble (d'appareillage de connexion et de commande)
sous enveloppe
ensemble comportant une paroi sur toutes ses faces latérales, supérieure et inférieure, de façon à assurer un degré de protection spécifié
NOTE – La surface de montage peut faire partie de l'enveloppe lorsqu'une publication particulière le spécifie.
[IEV number 441-12-0
Шкаф - защищенное НКУ, предназначенное для установки на полу
Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.
Safety enclosed switchgear may be classified with respect to purpose of application as follows:
1. General medium- or high-voltage switchgear
2. Primary unit substations
3. Rectifier unit substations
4. Secondary unit substations or power centers
5. General low-voltage switchgear
6. Low-voltage distribution switchboards
7. Motor-control-center switchboards
[American electricians’ handbook]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Обобщающие термины
Синонимы
EN
- enclosed assembly (of switchgear and controlgear)
- enclosed switchboard
- safety enclosed board
- safety enclosed switchgear
DE
FR
Англо-русский словарь нормативно-технической терминологии > enclosed assembly (of switchgear and controlgear)
-
15 safety enclosed switchgear
НКУ защищенное
НКУ закрытое со всех сторон (за возможным исключением монтажной поверхности), в котором после его установки обеспечивается степень защиты не менее IP2X.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
защищенное НКУ
НКУ, конструкция которого обеспечивает требуемую степень защиты со всех сторон от прикосновения к частям, находящимся под напряжением (за исключением монтажной поверхности).
[ ГОСТ Р МЭК 61439.1-2013]EN
enclosed assembly (of switchgear and controlgear)
an assembly enclosed on all sides, top and bottom in such a manner as to provide a specified degree of protection
NOTE – The mounting surface may form a part of the enclosure when specified in the relevant publication.
[IEV number 441-12-02]FR
ensemble (d'appareillage de connexion et de commande)
sous enveloppe
ensemble comportant une paroi sur toutes ses faces latérales, supérieure et inférieure, de façon à assurer un degré de protection spécifié
NOTE – La surface de montage peut faire partie de l'enveloppe lorsqu'une publication particulière le spécifie.
[IEV number 441-12-0
Шкаф - защищенное НКУ, предназначенное для установки на полу
Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.
Safety enclosed switchgear may be classified with respect to purpose of application as follows:
1. General medium- or high-voltage switchgear
2. Primary unit substations
3. Rectifier unit substations
4. Secondary unit substations or power centers
5. General low-voltage switchgear
6. Low-voltage distribution switchboards
7. Motor-control-center switchboards
[American electricians’ handbook]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Обобщающие термины
Синонимы
EN
- enclosed assembly (of switchgear and controlgear)
- enclosed switchboard
- safety enclosed board
- safety enclosed switchgear
DE
FR
Англо-русский словарь нормативно-технической терминологии > safety enclosed switchgear
-
16 primary distribution switchgear
комплектное устройство первичного распределения электроэнергии
-
[Интент]
Рис. ABBПараллельные тексты EN-RU
They are usually installed on the load side of MV/LV transformers or generators.
These assemblies include one or more incoming units, bus ties and a relatively reduced number of outgoing units.
There are also present measuring instruments and other switching and control equipment.
These assemblies have a sturdy structure to withstand the electrodynamic stresses and the weight of big sized apparatus.
As a matter of fact peculiar characteristics of the power center are high rated currents and shortcircuit currents.
The constructional type is a cubicle structure, with metal enclosure and sections divided into compartments with selective access.
[ABB]Такие устройства обычно подключают на стороне нагрузки СВ/НВ трансформаторов или генераторов.
В их состав входят один или несколько блоков ввода, шины и относительно небольшое число блоков вывода.
В состав комплектного устройства первичного распределения электроэнергии входят также измерительные приборы, коммутационные устройства и средства контроля состояния.
Данные комплектные устройства имеют прочную конструкцию, способную выдерживать электродинамическое действие токов и вес крупногабаритной аппаратуры.
Центры распределения электроэнергии характеризуются высокими номинальным током и током короткого замыкания.
С точки зрения конструктивного исполнения они представляют собой многошкафное комплектное устройство в металлической оболочке, состоящее из секций, каждая из которых разделена на отсеки с независимым доступом.
[Перевод Интент]Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.
Safety enclosed switchgear may be classified with respect to purpose of application as follows:
1. General medium- or high-voltage switchgear
2. Primary unit substations
3. Rectifier unit substations
4. Secondary unit substations or power centers
5. General low-voltage switchgear
6. Low-voltage distribution switchboards
7. Motor-control-center switchboards
[American electricians’ handbook]Тематики
- НКУ (шкафы, пульты,...)
- комплектное распред. устройство (КРУ)
EN
Англо-русский словарь нормативно-технической терминологии > primary distribution switchgear
-
17 arc-proof switchboard
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchboard
-
18 withdrawable solution
выдвижной функциональный блок
-
[Интент]Рис. Schneider Electric
Выдвижной функциональный блокПараллельные тексты EN-RU
The new withdrawable drawers with their integrated front face require no tools to handle them.
[Schneider Electric]Обращение с выдвижными блоками новой конструкции с установленной лицевой панелью выполняется без использования инструмента.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Шкаф с выдвижными блоками
Рис. Schneider Electric
Выдвижной блок
Рис. Schneider ElectricS afety enclosed switchgear of the truck or draw-out type (Figs. 4.113 and 4.114) consists of a steel enclosure mounted on an angle-iron framework. All apparatus which requires attention or inspection is mounted on a truck or draw-out structure.
FIGURE 4.113 Draw-out type of safety enclosed vacuum circuit-breaker switchgear
assembly.
[Siemens Energy & Automation, Inc.]
FIGURE 4.114 Draw-out type of vacuum circuit-breaker.
[Siemens Energy & Automation, Inc.]The equipment for each circuit is mounted on either a separate truck, which can easily be rolled out from the rest of the structure, or a metal structure supported on guides so that it can easily be slid in and out from the enclosure (Fig. 4.114).
[American electricians’ handbook]
Metal Clad Withdrawable Switchgear
[ http://en.daqo.com/Medium-Voltage-Switchgear-UR4_42.html]
Тематики
- НКУ (шкафы, пульты,...)
Обобщающие термины
EN
Англо-русский словарь нормативно-технической терминологии > withdrawable solution
-
19 plug-in switchboard system
Шкаф с выдвижными блоками
Рис. Schneider Electric
Выдвижной блок
Рис. Schneider ElectricS afety enclosed switchgear of the truck or draw-out type (Figs. 4.113 and 4.114) consists of a steel enclosure mounted on an angle-iron framework. All apparatus which requires attention or inspection is mounted on a truck or draw-out structure.
FIGURE 4.113 Draw-out type of safety enclosed vacuum circuit-breaker switchgear
assembly.
[Siemens Energy & Automation, Inc.]
FIGURE 4.114 Draw-out type of vacuum circuit-breaker.
[Siemens Energy & Automation, Inc.]The equipment for each circuit is mounted on either a separate truck, which can easily be rolled out from the rest of the structure, or a metal structure supported on guides so that it can easily be slid in and out from the enclosure (Fig. 4.114).
[American electricians’ handbook]
Metal Clad Withdrawable Switchgear
[ http://en.daqo.com/Medium-Voltage-Switchgear-UR4_42.html]
Тематики
- НКУ (шкафы, пульты,...)
Обобщающие термины
EN
Англо-русский словарь нормативно-технической терминологии > plug-in switchboard system
-
20 air blast circuit breaker
выключатель воздушного дутья
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
выключатель с воздушным дутьем
-EN
air blast circuit breaker
A circuit breaker using compressed air to force the extinction of the arc through an arc-chute system. An obsolete technology.
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Тематики
- высоковольтный аппарат, оборудование...
EN
Англо-русский словарь нормативно-технической терминологии > air blast circuit breaker
- 1
- 2
См. также в других словарях:
Switchgear — The term switchgear, used in association with the electric power system, or grid, refers to the combination of electrical disconnects, fuses and/or circuit breakers used to isolate electrical equipment. Switchgear is used both to de energize… … Wikipedia
Hawker Siddeley Switchgear — Infobox Company name = Hawker Siddeley Switchgear type = genre = foundation = 1888 as Brush Electrical Engineering Company founder = Charles Francis Brush location city = location country = location = origins = key people = area served = industry … Wikipedia
Circuit breaker — For other uses, see Circuit breaker (disambiguation). An air circuit breaker for low voltage (less than 1000 volts) power distribution switchgear … Wikipedia
комплектное распределительное устройство среднего напряжения — Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal enclosed switchgear and metal clad switchgear. Most safety enclosed boards are of the unit or sectional type. They consist … Справочник технического переводчика
НКУ с защитой от воздействия электрической дуги — комплектное устройство с защитой от электрической дуги низковольтное комплектное устройство с защитой от электрической дуги НКУ распределения и управления с защитой от электрической дуги [Интент] EN arc resistant switchgear A type of switchgear… … Справочник технического переводчика
Military equipment of Turkey — The military equipment of Turkey includes a wide array of arms, artilleries, large surface vessels, cannons, armored vehicles, mortars, unmanned vehicles and many different equipments. Contents 1 Historical development 1.1 General 1.2 1923 1950 … Wikipedia
НКУ с выдвижными блоками — Шкаф с выдвижными блоками Рис. Schneider Electric Выдвижной блок Рис. Schneider Electric Safety enclosed switchgear of the truck or draw out type (Figs. 4.113 and 4.114) consists of a steel enclosure mounted on an angle iron framework. All… … Справочник технического переводчика
Rowan Companies — Rowan Companies, Inc. (nyse|RDC), founded in 1923 and based in Houston, Texas, is an S P 500 company which provides contract oil well drilling services and rigs, and manufactures equipment for drilling as well as for mining and timber industries … Wikipedia
Vakuumschalter — für Mittelspannung (Dreiphasenausführung) … Deutsch Wikipedia
выключатель с воздушным дутьем — EN air blast circuit breaker A circuit breaker using compressed air to force the extinction of the arc through an arc chute system. An obsolete technology. [http://electrical engineering portal.com/glossary of medium voltage switchgear terms]… … Справочник технического переводчика
распределительное устройство среднего напряжения — — [Я.Н.Лугинский, М.С.Фези Жилинская, Ю.С.Кабиров. Англо русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.] Тематики электротехника, основные понятия EN medium voltage switchgear … Справочник технического переводчика